https://www.bihl-wiedemann.de/en/company/technological-foundations/bus-systems/canopen.html | BingShi

https://www.bihl-wiedemann.de/en/company/technological-foundations/bus-systems/canopen.html

Logo Bihl+Wiedemann GmbH

CANopen Fieldbus system

What is CANopen?

CANopen is an open fieldbus standard based on CAN which is used mainly in automation technology. CANopen enables communication between devices made by different manufacturers without any special interface adaptations.

CANopen Products

CANopen ASi Gateways

CANopen ASi-3 gateways in stainless steel provide an interface for a CANopen fieldbus. These ASi gateways are available in various versions with IP20 protection rating.

CANopen ASi

Figure Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C
Article No.
BWU1823Gateway IP20CANopen2 ASi networks, 2 ASi Mastersyes, max. 4 A/ASi networkRS 232yesyesno
BWU1822Gateway IP20CANopen2 ASi networks, 2 ASi Mastersno, max. 8 A/ASi network, redundant supplyRS 232yesyesno
BWU1821Gateway IP20CANopen1 ASi network, 1 ASi Masterno, max. 8 A/ASi networkRS 232yesyesno

 

Safety, CANopen ASi Gateway

Safety, CANopen ASi

Figure Model

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Standard devices

"Single Master":

1 ASi network, 1 ASi Master.

"Double Master":

2 ASi networks, 2 ASi Masters.

Safety devices

"Single Master" :
1 ASi network, 1 ASi Master.

"Double Master" :
2 ASi networks, 2 ASi Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":
Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"no, max. 8 A/ASi network, redundant supply ":
1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.

" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies

"USB":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface.

"Ethernet fieldbus"

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface.

"Ethernet fieldbus + Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface.

"Ethernet diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface.

"Ethernet diagnostic + Modbus TCP diagnostic":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface.

For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor.

"Ethernet fieldbus + RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.


"RS 232":

Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface.


The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device.

Diagnostic and configuration interface

Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device.

Recognition of duplicate ASi addresses

Checks the ASi line for interference effects such as noise, external voltages, ...

ASi fault detector

Using a C-program offers the possibility to run mini-PLC functions with a gateway.

Programming in C

An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes.

Inputs digital, EDM
Inputs Safety, SIL 3, Cat. 4 Inputs safety, expandable to Outputs Safety, SIL 3, cat. 4 Safety outputs, independent according to SIL 3, expandable to Safety communication Article No.
BWU2804Gateway with integrated Safety MonitorIP20CANopen1 ASi network, 1 ASi Masteryes, max. 4 A/ASi networkEthernet diagnosticyesyesoptional63 x 2 channelsmax. 31 x 2 channels, max. 1891 in max. configuration6 release circuits, 6 x electronic safe outputsmax. 31, max. 991 in max. configurationSafe Link

 

CANopen Master Simulator

The CANopen Master Simulator is a simple, universal tool for exchanging data with CANopen slaves from virtually any manufacturer without a CANopen master, by just using a PC and the delivered hardware. Input data can be read and output data written without any additional entries or files.

 

In addition, the CANopen Master Simulator can be used of course to read and write special objects. It is also possible to search a complete CANopen line for any connected slaves. The digital I/O data are represented in hex and binary as well as ASCII characters. Analog I/O data are represented in decimal. Output data can be sent consistently.

 

Included with the CANopen Master Simulator package is the CAN dongle. The CAN dongle is the ideal interface converter between the USB port on the PC and CANopen. The dongle is very compact and is powered by the USB port on the PC. This also makes it ideal for portable use with a laptop or notebook.

更多文章...
https://wilo.com/id/en/Solutions-Finder/Connectivity/Building-automation/CANopen/ https://de.wikipedia.org/wiki/EtherCAT https://www.infineon.com/dgdl/Infineon-Peripheral+-+EtherCAT+Slave+Controller+(ECAT)-TR-v01_00-EN.pdf?fileId=5546d4625696ed7601569c8617fb08ba https://www.deltaww.com/zh-TW/products/06020302/ALL/ https://wilo.com/id/en/Solutions-Finder/Connectivity/Building-automation/Modbus/
评论
Powered by Odoo, the #1 Open Source eCommerce.
Copyright © bingshi